Understand the system before voltage is applied.
See how the HV battery, power electronics and disconnection points work together.
See how the HV battery, power electronics and disconnection points work together.
Practise each step on the trainer and transfer it safely to real applications.
Use realistic test points and measuring devices to assess integrated faults.
The aim: to develop the practical and diagnostic skills needed to safely isolate, measure, and troubleshoot HV systems before working on a real vehicle.
Operating states, contactor positions and measurement points become clear. Equipotential bonding and diagnostic tasks can be practised safely.
Provide structured training in direct and indirect procedures on high-voltage and low-voltage systems.
Identify, measure and professionally assess typical faults encountered in workshop practice.
Consolidate procedures and decision-making within the training system before learners work on real vehicles.
Store vehicle keys securely with a padlock and protect them from unauthorised access.
Removable inverter cover for open-circuit, insulation and milliohm measurements.
Start the system using the start button and monitor the pre-loading process via the status LEDs.
The LOTO Trainer for HV Vehicles enables practical training in key high-voltage disconnection procedures without requiring an actual vehicle.
Disconnection procedures can be safely repeated, typical faults can be specifically simulated, and key work steps can be systematically practised.
The training system draws on components and system interrelationships from CarTrain ‘Diagnosis and Repair of High-Voltage Vehicles’ (AHV25CT). Existing CarTrain users will therefore quickly become familiar with the technology and can apply their existing understanding of the system to the disconnection process.
Explore disconnection methods and key system components.
Practise direct and indirect HV disconnection procedures.
Perform insulation and milliohm measurements safely.
Investigate integrated fault scenarios systematically.
Apply knowledge to CarTrain and real applications.
Every training programme has different requirements. Together with you, we tailor the learning system to your learning objectives, technical focus and specific application. Simply send us an enquiry to receive further information.
Explain commissioning procedures, system architecture and high-voltage measurement technology in a clear and accessible way. Suitable for lessons, project work and independent practice.
Practise activation and measurement procedures in a repeatable manner and firmly consolidate key steps.
To prepare skilled workers for the safe handling of high-voltage systems and further practical applications.
Trainees analyse the system structure, carry out commissioning procedures, apply high-voltage measurement techniques and diagnose system faults. In this way, they combine specialist knowledge with safe working practices.
Competence is developed through repeated practice on a system that closely resembles reality.
We will discuss with you how the high-voltage disconnection trainer fits in with your target audience, learning objectives and existing laboratory facilities.
Common activation options within a system
Up to ten real-world examples of errors
Compact design for immediate use at the learning station
From training goals to the right equipment
Please discuss with us your target audience, spatial concept, scope of facilities and desired training content.
Non-binding and personalised
Learners analyse high-voltage batteries, power electronics, low-voltage disconnection points and the control display within the context of the system as a whole.
Analysing system architecture in a structured manner
Clearly identify activation statuses
Assign measurement points and components
Learners carry out commissioning procedures, measure actual resistances and identify system faults.
Real hardware and practical test points
Repeatable processes for greater routine
Understanding through measurement, evaluation and decision-making
A compact training system that enables learners to safely de-energise high-voltage and low-voltage systems using common configurations, carry out measurements and diagnose faults.
Trainees analyse the system configuration, carry out commissioning procedures, apply high-voltage measurement techniques and identify faults in high-voltage systems.
The equipment includes the LOTO trainer, an insulation tester, a milliohmmeter and the associated training and learning materials.
The integrated fault simulation reproduces up to ten faults encountered in workshop practice. Learners systematically identify, measure and assess them.
These include:
Training covers direct and indirect disconnection methods for high-voltage and low-voltage systems, including the HV and LV service disconnects, the HV fuse, diagnostic tester-guided disconnection and emergency disconnection using the cutting loop.
The training programme is aimed at vocational schools, specialist vocational schools, industrial training centres and in-house training centres.
The unit is designed as a compact tabletop system. Dimensions: 460 mm wide, 300 mm deep and 130 mm high.
The activation trainer is ready for immediate use without a computer.